Quick Change Reverse Osmosis Drinking Water System
Installation, Operation & Service Instructions with Part List
Models: QCRO4V-50
QCRO4V-50-PL
QCRO4V-75
QCRO4V-75-PL
www.pura.com
QCRO4V-50 system certified by WQA to NSF/ANSI 58 and
CSA B483.1 for the reduction of the following substances,
as verified and substantiated by test data: Arsenic V,
Barium, Cadmium, Chromium III and VI, Copper, Fluoride,
Lead, Radium 226/228, Selenium, TDS and Turbidity.
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - QCRO4V-75-PL

Quick Change Reverse Osmosis Drinking Water SystemInstallation, Operation & Service Instructions with Part ListModels: QCRO4V-50 QCRO4V-50-PL QC

Page 2 - Serial Number

8OR3X2X 1. RO Manifold with Flow Control 2. Sediment Filter 3. Carbon Block Filter 4. RO Membrane 5. Carbon Block Filter 6. Metal or Plast

Page 3 - Table of Contents Page

9Tubing ConnectorsThe PURA system features reliable and convenient push-to-connect tubing connectors. Tubing is easily connected and disconnected fro

Page 4

10Verify Flow Control LocationThe RO manifold comes attached with the elbow fitting flow control. This flow control is attached to the manifold by qui

Page 5 - Table 1

113/8” White TubingStorage Tank PreparationNOTE: Changing the air pressure will alter the amount of water stored in the tank. Increasing the pressure

Page 6

12The following steps will enable you to install the system quickly and orderly. Some variation may be necessary depending on the installation. See pa

Page 7 - Performance Data Sheet

13Step 2 – Faucet InstallationTo simplify its access and installation, we suggest you install the faucet on the rear lip of the sink. It should be eve

Page 8 - Figure 1

141/4” Red Tubing3/8” Red TubingFaucetBase(Remove white protective film.)Split WasherDrain Line from RO Manifold(1/4” Red Tubing)Drinking Water Line t

Page 9 - Figure 2

15FaucetBase(Remove white protective film)Plastic WasherLarge Rubber WasherSmall Rubber WasherNutFaucet AdapterLock Washer13567824Standard Fau

Page 10 - Figure 3

16Remove white protective film from faucet base. Verify faucet body, metal base, and rubber base washer are in place above sink (Items 1, 3, and 2).Lo

Page 11 - Product Information

171/4” Red TubingStep 3 – Install Adapter Valve on Water SupplyStep 4 – Connect System DrainPlumbing codes require that the drain from reverse osmosi

Page 12

Safe PracticesThroughout this manual there are paragraphs set off by special headings.NOTE: Note is used to emphasize installation, operation or main

Page 13 - Installation

182341Many homes are equipped with disposals and dishwashers. Special care must be taken when these appliances are present to prevent improper air

Page 14

19Step 6 – Install Filter System AssemblyThe mounting bracket contains four mounting slots. The holes are sized to accept #10 round head wood screws

Page 15 - Step 2 – Faucet Installation

2044. Connect the 1/4” OD red tubing from the air gap inlet of the faucet to the concentrate outlet on the RO manifold.RedStep 7 – Start-Up 1. Sani

Page 16 - Figure 10

21The performance of the PURA system can be characterized and judged by the quality and quantity of the water produced by the system. By measuring the

Page 17 - Standard Faucet Installation

22Pressure TankPura FaucetCold Water SupplyRO ManifoldDrain ConnectionBooster PumpFigure 181/4” Feed Line (White)3/8” ProductWater Line (Blue)3/8” Tan

Page 18 - Air Gap Faucet Installation

23NOTE: The reverse osmosis membrane (Stage 3) Part # 41407003 is recommended to be changed once every three years or as needed.Service ScheduleTo k

Page 19 - Step 4 – Connect System Drain

241. Turn off incoming water supply to RO.2. Open RO Faucet and allow water to drain from the tank until it is completely empty.3. Check that air

Page 20 - Figure 14

25Parts Breakdown# Item # Description Qty.1 134040R Manifold, Quick Change RO, 4 Stage 12 92223 Valve, Auto Shut-off 13 41407553 Fitting,Check Valve,Q

Page 21 - Figure 15

2612131415111016171920181256789342X3XOther Parts 1. Storage Tank – Part # 92371 2. Faucet & Hardware – Part # 92192 3. Drai

Page 22 - Step 7 – Start-Up

27If a problem cannot be corrected through the use of this troubleshooting guide please have the following information ready prior to calling the 1-80

Page 23 - Performance Measurements

1Table of Contents PageSpecifications and Performance Data Sheet ... 2Suggested Install

Page 24 - Pressure, Pressure, Pressure

28Problem Possible Cause Remedy4. External leakage. a. Tubing not fully seated in fitting a. Check all fittings for tightness.b. Tubing abraded in

Page 25 - Service and Maintenance

29PURA GuaranteeSubject to the conditions and limitations described below, WaterGroup warrants its PURA Reverse Osmosis Drinking Water Treatment Syste

Page 26

WaterGroup Companies, Inc.580 Park StreetRegina, SK, S4N 5A9, CanadaUSA Office:193 Osborne RoadFridley, MN, 55432, USAwww.pura.com55025.0113

Page 27

2Specifications and Performance Data SheetModel # Part # Stage 1 Stage 2 Stage 3 Stage 4 Storage Tank FaucetQCRO4V-50 1340302-60Sediment FilterActiva

Page 28

3 19.8"9.2"Product Water Storage Tanks15.8”2.0”4.7”14.3”2.5”13.1”Dimensions13.7"13.7"NOTES1. A booster is strongly recommended to

Page 29 - Troubleshooting Guide

4Filter Cartridge Specifications * The performance and life of a reverse osmosis membrane or filter element is highly dependent upon pressure, tempe

Page 30

5Performance Data Sheet† This appliance has been tested for the treatment of water containing pentavalent arsenic (also known as As(V), As(+5), or ars

Page 31 - PURA Guarantee

6Suggested Installation Equipment Recommended Tools 1. Utility Knife 2. Flathead Screwdriver 3. Phillips Screwdriver 4. Center Punch 5. 7/8

Page 32 - 55025.0113

7Overview of the PURA Quick Change RO System’s Components Manifold Assembly The manifold assembly serves as the functional hub of the PURA system by d